Description
A line of Hudson Surface Technology cost-effective, high-performance tools for MALDI-TOF (Matrix Assisted Laser Desorption Ionization - Time of Flight) Mass Spectrometry and proteomics. Get better results, in less time, at less cost and greater convenience with HST products.
μFocus technology is at the heart of HST's product line for MALDI-TOF MS. Unique, proprietary technology produces thin, disposable, single-use stainless steel targets with hydrophilic islands (μFocus spots) on a hydrophobic surface. The results is precise, concentrated, deposition of sample in precise, well-formed spots.
μFocus targets give you a precisely formed dried droplet spot of predetermined size. You can work with larger (1700-2000 μm) spots and use standard spotting techniques. You can also work with much smaller spots (700-900 μm) that allow you to reduce the amount of matrix used, to maintain optimum matrix to analyte ratio with less concentrated or smaller analyte samples. Many users report 5-10x increases in sensitivity. Because μFocus spots are uniform, you also see improvements in spot-to-spot reproducibility, making quantitative analysis and fingerprint assays more reliable.
Features
µFocus® MALDI Targets
Patterned hydrophobic and hydrophilic surfaces focus sample deposits to predefined spots with predefined sizes.Controlled size deposits reduce matrix demand, increasing analyte/matrix ratios.
- Sensitivity
- Productivity
- Economy
- High Throughout
- Imaging
You Get: increased signal/noise and greater instrument sensitivity.
Low-cost manufacturing on thin stainless steel plates translates into high-performance in a economical, single-use target.
You Get: Saving and productivity - more experiments in progress, less time spent cleaning plates, reduced costs for heavy sample traffic.
µFocus MALDI Sample Plates
Hydrophobic & Hydrophilic Patterning
Small, Uniform Matrix Deposition
Reduced Matrix - Increased Analyte Concentration
Single use Pricing - No Ghosting, No Clean up
µArray MALDI Sample Plates
- Dense Spot Array - HTS
- uFocus Technology - Sensitivity
- Single Use Pricing
- Imaging
Functional Surfaces
Advance separation technology for your experimental needs. Focus on your core expertise, not separations and preparation. Fast, economical access to affinity technology.
Non-focus plates are either stainless steel blanks (non-hydrophobic) or are fully hydrophobic (no μFocus spots). HST makes these available for your convenience; most often, they are utilized in LC-MALDI work.
MALDI-TOF Supplies | |||||||||||
Part No. | Series | Type | Dim | Spot Size | Thickness | pkg of | Picture | Quantity In Stock |
UOM | Price | Order |
---|---|---|---|---|---|---|---|---|---|---|---|
µFocus | |||||||||||
PFA0107000 | AB Sciex 4700/voyager | 8*8 wells 700um | 44x44mm | 700μm | 0.3t | 10 | 0*Lead time for this non-stock item is approximately 7 days. | PK | $270.00 | ||
PFA0110000 | AB Sciex 4700 /voyager | 8*8 wells 1000um | 44x44mm | 1000μm | 0.3t | 10 | DISCONTINUED | PK | --- | --- | |
PFA0124000 | AB Sciex 4700 /voyager | 8*8 wells 2400um | 44x44mm | 2400μm | 0.3t | 10 | DISCONTINUED | PK | --- | --- | |
PFA0207000 | AB Sciex 4700 / voyager | 12*12 wells | 44x44mm | 700μm | 0.3t | 10 | DISCONTINUED | PK | --- | --- | |
PFA0210000 | AB Sciex 4700 / voyager | 12*12 wells | 44x44mm | 1000μm | 0.3t | 10 | DISCONTINUED | PK | --- | --- | |
PFA0307000 | AB Sciex 4700 / voyager | 12*16 wells | 44x44mm | 700μm | 0.3t | 10 | DISCONTINUED | PK | --- | --- | |
PFA0310000 | AB Sciex 4700 / voyager | 12*16 wells | 44x44mm | 1000μm | 0.3t | 10 | DISCONTINUED | PK | --- | --- | |
PFA0406000 | AB Sciex 4700 / voyager | 24*24 wells | 44x44mm | 600μm | 0.3t | 10 | DISCONTINUED | PK | --- | --- | |
PFA2307000 | AB Sciex 4800 5800 | 384 circles | 123x80.7mm | 700μm | 0.3t | 5 | 0*Lead time for this non-stock item is approximately 7 days. | PK | $825.00 | ||
PFA2309000 | AB Sciex 4800 5800 | 384 circles | 123x80.7mm | 900μm | 0.3t | 5 | DISCONTINUED | PK | --- | --- | |
PFA2317000 | AB Sciex 4800 5800 | 384 circles | 123x80.7mm | 1700μm | 0.3t | 5 | DISCONTINUED | PK | --- | --- | |
µArray | |||||||||||
PSU0106000 | 4800 Slide Glass type | 5*16 circles | 25x75mm | 600μm | 0.3t | 10 | DISCONTINUED | PK | --- | --- | |
PSU0110000 | 4800 Slide Glass type | 5*16 circles | 25x75mm | 1000μm | 0.3t | 10 | DISCONTINUED | PK | --- | --- | |
PSU0126000 | 4800 Slide Glass type | 5*16 circles | 25x75mm | 2600 | 0.3t | 10 | 0*Lead time for this non-stock item is approximately 7 days. | PK | $195.00 | ||
Accessories | |||||||||||
HHA0201000 | AB Sciex 4800 5800 | Magnetic Height Adjuster | 1 | DISCONTINUED | EA | --- | --- | ||||
HSA0201000 | AB Sciex 4800 5800 | Slide Glass Guide for 2 pieces | 123x80.7mm | 1.0t | 1 | 0*Lead time for this non-stock item is approximately 7 days. | EA | $199.50 | |||
HMA0101000 | AB Sciex 4700 / voyager | Magnetic Holder | 58.5x58mm | 3.0t | 1 | 0*Lead time for this non-stock item is approximately 7 days. | EA | $299.00 | |||
PSB0110000 | 4800 Slide Glass type | Magnetic Base for HST Array plate | 25x75mm | 1.0t | 1 | DISCONTINUED | EA | --- | --- | ||
PSG0103000 | 4800 Slide Glass type | Nonfocus HST Array for imaging | 25x75mm | 0.3t | 10 | DISCONTINUED | PK | --- | --- | ||
* Lead time for this non-stock item is approximately 7 days. † Call for availability. | |||||||||||
Ordering information. International (non-US) prices available through your local dealer. |